Ventilation Testing
As buildings become increasingly airtight to save energy, proper ventilation is critical to ensure healthy indoor air quality and prevent problems with damp and mould. Under Approved Document Part F of the Building Regulations, mechanical ventilation testing (or flow rate testing) is a mandatory requirement for all new-build domestic properties. This ensures that extractor fans, continuous mechanical extracts, and MVHR systems are actually moving the correct volume of air specified in the design.
At Energytest, we carry out calibrated ventilation testing alongside our air leakage testing, providing you with the combined compliance certificates needed for Building Control sign-off.

Intermittent
Extract Fans
Intermittent extract fans are designed to operate briefly (typically triggered by a light switch or a humidity sensor). Under Part F of the Building Regulations, these local background fans must achieve specific minimum flow rates. Using precision, calibrated vane anemometers and capture hoods, we measure the airflow of each fan to ensure they are extracting efficiently and meet Part F Building Control standards.
Continuous (dMEV)
Extract Fans
Decentralised Mechanical Extract Ventilation (dMEV) fans are continuously running, low-energy extractor fans installed directly in wet rooms. They constantly extract air at a low "trickle" rate to maintain continuous air changes, boosting to a higher purge rate when needed. Testing these systems requires measuring both the continuous trickle flow rate and the maximum boost rate. We ensure your dMEV installations are calibrated to meet Part F Building Control requirements.
Mechanical Ventilation Heat Recovery (MVHR)
Mechanical Ventilation with Heat Recovery (MVHR) is a centralised system that extracts stale, moist air from wet rooms while supplying fresh, filtered air to living spaces. Crucially, the system uses a heat exchanger to warm the incoming fresh air using heat recovered from the outgoing air. Testing an MVHR system involves a comprehensive balancing act; we must meticulously measure and test the airflow rates at every single supply and extract valve throughout the property to meet Part F compliance.
All of our engineers are NICEIC trained and qualified.
Our service includes all the support required to ensure compliance is achieved.